DRIWON DN-9500 Grade 1 – a heavy duty stairwell door closer that closes and positively latches fire-rated stair doors from any open position, every time. UL listed and 3-hour fire rated on rated assemblies, adjustable from size 1 to 6 for standard and pressurized stairwells.
For office towers, hospitals, schools, hotels, apartment buildings, parking structures and every building with enclosed exit stairs.
Exit enclosures & stair towers
Tested beyond 2 million cycles
With delayed action & positive latch
On rated door assemblies




Stair doors are the most code-sensitive doors in most buildings. An enclosed exit stair is a protected escape route: if one door is propped open or fails to latch, smoke can fill the stair on every floor. That is why stair doors must be self-closing and positively latching, and why fire marshals check them first during inspections. The closer is part of the listed fire door assembly, so it must be UL listed for use on rated doors.
In high-rise buildings, stairs are often pressurized to keep smoke out, and stack effect pushes air through stair doors all winter. Both create pressure on the door. The closer needs enough power and a firm latch speed to close against it, yet NFPA 101 limits the force needed to open egress doors (in general, 30 lbf to set the door in motion and 15 lbf to release the latch). The way to balance both is an adjustable closer, set with the pressurization system and HVAC running, then verified with a door pressure gauge.
Under the 2010 ADA Standards for Accessible Design (section 404), interior hinged doors must open with no more than 5 lbf, and a closer must be adjusted so the door takes at least 5 seconds to swing from 90° to 12° from the latch. Fire doors are the exception on opening force: the authority having jurisdiction sets the minimum. Always check local code and your AHJ.
Learn more in our guides to fire-rated door closers (UL and NFPA 80) and door closer mounting types. Stair doors in tall buildings are covered on our office building and apartment pages, and exposed stair towers on our parking garage page.
| Model | DRIWON DN-9500 extra heavy duty commercial door closer |
|---|---|
| Certification | ANSI/BHMA A156.4 Grade 1; UL listed |
| Fire rating | 3-hour fire rated when installed on a rated door assembly |
| Power size | Adjustable 1–6 |
| Door weight | 44–440 lbs (20–200 kg) |
| Door width | 23"–59" (58–150 cm) |
| Body / arm | Extra heavy duty cast iron body, wrought steel arm, heat-treated piston |
| Control | Hydraulic, with delayed action and secure positive latch |
| Finish | Corrosion-resistant powder coat, silver or black |
Need the lighter-duty option for interior doors? See the DRIWON DN-8220 Grade 1 door closer. Full details on the DN-9500 product page.
Yes. Doors in enclosed exit stairs are fire door assemblies and must be self-closing and positively latching under NFPA 80 and the IBC.
Only with a hold-open device that releases automatically on fire alarm or smoke detection. Wedges and kick-down stops are not allowed on fire doors.
Typically 60 minutes in 1-hour stair enclosures and 90 minutes in 2-hour enclosures, depending on building height and code. Check the door and frame labels.
Most 36" hollow metal stair doors use a size 3–4 setting; heavier, wider or pressurized doors need 4–6. The DRIWON DN-9500 adjusts from 1 to 6.
Usually stair pressurization, stack effect or a misaligned frame. Fix alignment first, then increase latch speed, and only then raise the power size.
It is UL listed and 3-hour fire rated when installed on a rated door assembly, which covers standard 60- and 90-minute stair doors.