Buy DN-9500 on Amazon
EspaΓ±ol

Heavy Duty Commercial Entrance Door Closers
for Office Buildings

DRIWON DN-9500 Grade 1 – a commercial entrance door closer for office towers and corporate campuses: lobbies, tenant corridors, stairwells and emergency exits. Smooth, reliable operation under constant daily use.

Built for office towers and corporate campuses across the U.S.

πŸ›‘οΈ ANSI / BHMA Grade 1
πŸ”₯ 3-Hour Fire Rated
πŸ› οΈ Extra Heavy Duty Cast Iron

🏒 Built for Office Buildings

Main entrances, lobbies & corridors

πŸ† Grade 1 Extra Heavy Duty

Tested beyond 2 million cycles

βš™οΈ Fully Adjustable 1-6

Smooth closing for office traffic

πŸ”₯ UL 3-Hour Fire Rated

On rated door assemblies

DRIWON DN-9500 – Commercial Entrance Door Closer, Heavy Duty (Grade 1)

  • βœ… COMMERCIAL ENTRANCE DOOR CLOSER, HEAVY DUTY
    Built for high-traffic office entrances, lobbies and corporate hallways.
  • βœ… EXTRA HEAVY DUTY PERFORMANCE
    Cast iron body with reinforced steel arm for repeated daily cycles.
  • βœ… SMOOTH & CONTROLLED CLOSING
    Adjustable size 1–6 with delayed action and positive latch for employees and visitors.
  • βœ… GRADE 1 CERTIFIED & FIRE RATED
    ANSI/BHMA A156.4 Grade 1 and UL listed. 3-hour fire rated on rated door assemblies.
  • βœ… IDEAL FOR OFFICE APPLICATIONS
    Main entrances, lobby, corridor and stairwell doors. Doors 44–440 lbs and 23"–59".
Buy DN-9500 on Amazon

Choosing a Door Closer for Office Lobbies, Tenant Entrances and Corridors

An office building has very different doors under one roof: heavy glass or metal lobby entrances, lighter tenant suite doors, and fire-rated stair and corridor doors. A single Grade 1 adjustable closer simplifies purchasing: size 1–6 power lets you set each door correctly.

Stack Effect, Wind and Accessibility in Tall Buildings

In high-rise buildings, temperature differences between inside and outside create a stack effect that pushes air through lobbies and stairwells. This can make doors hard to close or hard to open. Use an adjustable closer, set the latch speed so the door fully latches, and then verify opening force.

Under the 2010 ADA Standards for Accessible Design (section 404), interior hinged doors must open with no more than 5 lbf, and a closer must be adjusted so the door takes at least 5 seconds to swing from 90Β° to 12Β° from the latch. Fire doors are the exception on opening force: the authority having jurisdiction sets the minimum. Always check local code and your AHJ.

Stair and corridor fire doors must self-close and latch (NFPA 80, NFPA 101). The DN-9500 is UL listed and 3-hour fire rated when used on a rated assembly.

Specifying for Property Managers and Contractors

  1. Audit door weights and widths by floor and by door type.
  2. Separate fire-rated openings from standard ones.
  3. Use one closer model across tenants to simplify service.
  4. Keep spares on site for lobby and stair doors.

Managing a portfolio? Ask us for volume pricing.

Tenant Suite Entries and Corridors

Suite entry doors are the most-used doors in a multi-tenant office building. Whether they must be self-closing depends on whether the corridor is rated, which varies with occupancy, sprinklers and the code edition, so check with the building official. Even where not required, closers keep suites secure and quiet. Landlords often specify one closer model in tenant design criteria; the DN-9500 suits busy entries and the aluminum DN-8220 suits interior suite doors.

Stairs, IT Rooms and Building Services

Office towers rely on stairwell doors that close and latch against stack effect and stair pressurization, on server rooms and IT closets that must stay closed for security and fire suppression (see data center and server room door closers), and on mechanical, electrical and loading dock doors that take heavy use. Garages under office buildings add pressurized lobby doors; see underground parking garages.

DRIWON DN-9500 Specifications

ModelDRIWON DN-9500 extra heavy duty commercial door closer
CertificationANSI/BHMA A156.4 Grade 1; UL listed
Fire rating3-hour fire rated when installed on a rated door assembly
Power sizeAdjustable 1–6
Door weight44–440 lbs (20–200 kg)
Door width23"–59" (58–150 cm)
Body / armExtra heavy duty cast iron body, wrought steel arm, heat-treated piston
ControlHydraulic, with delayed action and secure positive latch
FinishCorrosion-resistant powder coat, silver or black

Need the lighter-duty option for interior doors? See the DRIWON DN-8220 Grade 1 door closer. Full details on the DN-9500 product page.

Office Building Door Closer FAQ

What is the best commercial entrance door closer for an office lobby?

A Grade 1 heavy duty hydraulic closer with adjustable size 1–6, like the DRIWON DN-9500, tuned for the door's weight and wind exposure.

Why is my lobby door hard to close in winter?

Stack effect and pressure differences can resist the door. Adjust the latch speed and power size, and confirm opening force.

Is the DN-9500 suitable for stairwell fire doors?

Yes, on rated assemblies. It is UL listed and 3-hour fire rated.

Do you supply property managers in bulk?

Yes. Use the form below.

Do office suite entry doors need door closers?

If the corridor is fire rated, yes. Otherwise it depends on local code and landlord standards; many buildings use closers for security and noise control anyway.

Which closer is best for interior office doors?

The aluminum DN-8220 is a versatile Grade 1 choice for interior suite doors; use the cast iron DN-9500 for lobbies, stairs and service doors.

Do server room doors in an office need closers?

Usually yes, for access control, fire separation and clean agent suppression. See our data center page.

Bulk Orders & Professional Inquiries

Need multiple DN-9500 units for office buildings, corporate lobbies, or commercial entrance projects? Contact our team for volume pricing, specifications, and fast supply.