DRIWON DN-9500 Grade 1 β an industrial door closer for factories, warehouses and production areas. Cast iron body and a heat-treated piston for heavy doors, dust, vibration and constant use.
Built for industrial facilities and manufacturing plants across the U.S.
Factories, warehouses & production areas
Tested beyond 2 million cycles
Controlled closing for heavy doors
On rated door assemblies




Industrial doors are heavy, abused and often exposed to dust, vibration, temperature swings and forklift or cart traffic. They also separate areas with different hazards, noise levels or climate. A door that does not close is a safety and efficiency problem. The DN-9500 is built for this: a cast iron body, a wrought steel arm and a heat-treated piston for long life.
OSHA exit route rules require that exit doors can be opened from the inside without keys or special knowledge, and fire doors in rated separations must close and latch as designed (see NFPA 80). The DN-9500 is UL listed and 3-hour fire rated on rated door assemblies. Closers should never be disabled with a wedge or a hold-open hack: where hold-open is needed on a fire door, use a listed hold-open or magnetic device.
Under the 2010 ADA Standards for Accessible Design (section 404), interior hinged doors must open with no more than 5 lbf, and a closer must be adjusted so the door takes at least 5 seconds to swing from 90Β° to 12Β° from the latch. Fire doors are the exception on opening force: the authority having jurisdiction sets the minimum. Always check local code and your AHJ.
For multi-site rollouts, contact us for volume pricing.
Distribution centers combine long exterior walls, dock areas and constant forklift traffic. Personnel doors next to dock doors are hit by wind every time an overhead door opens, so they need firm backcheck and enough power to latch in a draft (see exterior door closers). Doors between the warehouse and offices, break rooms or battery-charging areas are often fire rated and must self-close. Wide equipment doors benefit from delayed action.
Dusty production areas shorten the life of exposed arms and pivots, so wipe down closers on a schedule. In washdown areas, protect closers from direct spray and choose a corrosion-resistant finish. Freezers and walk-in coolers are specialty applications: standard hydraulic closers are not intended for sub-zero rooms, so use hardware rated for the temperature. For the heaviest steel doors see our heavy door and hollow metal door closer pages.
| Model | DRIWON DN-9500 extra heavy duty commercial door closer |
|---|---|
| Certification | ANSI/BHMA A156.4 Grade 1; UL listed |
| Fire rating | 3-hour fire rated when installed on a rated door assembly |
| Power size | Adjustable 1β6 |
| Door weight | 44β440 lbs (20β200 kg) |
| Door width | 23"β59" (58β150 cm) |
| Body / arm | Extra heavy duty cast iron body, wrought steel arm, heat-treated piston |
| Control | Hydraulic, with delayed action and secure positive latch |
| Finish | Corrosion-resistant powder coat, silver or black |
Need the lighter-duty option for interior doors? See the DRIWON DN-8220 Grade 1 door closer. Full details on the DN-9500 product page.
A Grade 1 extra heavy duty hydraulic closer with a cast iron body, like the DRIWON DN-9500, rated for doors up to 440 lbs.
Do not wedge or disable a closer on a fire door. Use a listed hold-open device if needed.
The DN-9500 handles doors from 44β440 lbs and 23"β59" wide.
Yes. Use the form below.
A cast iron Grade 1 closer with firm backcheck and high power, such as the DN-9500, to handle wind when dock doors open.
Standard hydraulic closers are not intended for sub-zero rooms. Use hardware rated for the low temperature.
Wipe the body and arm regularly, check fasteners and valves during safety audits and replace units that leak or close sluggishly.
Need multiple DN-9500 units for factories, warehouses, or industrial facilities? Contact our team for volume pricing, specifications, and fast supply.