Buy DN-9500 on Amazon
EspaΓ±ol

Heavy Duty Door Closers
for Data Centers & Server Rooms

DRIWON DN-9500 Grade 1 – a heavy duty door closer for data centers, colocation facilities, server rooms and IT closets, where every door must close and latch so access control, door alarms and fire suppression work as designed.

For enterprise and colocation data centers, telecom and network rooms, server rooms and IT closets in offices, hospitals and campuses.

πŸ›‘οΈ ANSI / BHMA Grade 1
πŸ”₯ 3-Hour Fire Rated
πŸ› οΈ Extra Heavy Duty Cast Iron

πŸ–₯️ Built for Data Centers

Secure suites & IT rooms

πŸ† Grade 1 Extra Heavy Duty

Tested beyond 2 million cycles

βš™οΈ Fully Adjustable 1-6

With delayed action & positive latch

πŸ”₯ UL 3-Hour Fire Rated

On rated door assemblies

DRIWON DN-9500 – Data Center & Server Room Door Closer (Grade 1)

  • βœ… DATA CENTER DOOR CLOSER
    Built for perimeter, data hall, server room and MEP doors.
  • βœ… RELIABLE POSITIVE LATCH
    Doors close fully so card readers, electric strikes and door position switches work.
  • βœ… ROOM INTEGRITY
    Helps keep doors closed in clean agent and pressurized rooms.
  • βœ… GRADE 1 & UL 3-HOUR
    For fire-rated IT rooms and corridors.
  • βœ… HEAVY & WIDE DOORS
    Equipment doors up to 440 lbs and 59" wide.
Buy DN-9500 on Amazon

Why Door Closers Matter in a Data Center

In a data center, a door that does not close is a security incident, an airflow problem and potentially a fire protection failure. Access control, video and door alarms only work if the door actually latches. A Grade 1 closer with a reliable positive latch is a small part of the hardware set, but every other system depends on it.

Clean Agent Rooms and Room Integrity

Many server rooms are protected by clean agent fire suppression. These systems depend on the room holding the agent for a set time, so doors must be closed when the system discharges. Self-closing, latching doors and good seals are part of room integrity; the closer must have enough power to close against seals and any pressure. Coordinate with your fire protection engineer and the room integrity test.

Airflow, Containment and Pressure

Cooling designs keep the data hall at a controlled pressure. Doors that stand ajar waste cooling and can trip alarms. Set the closer with HVAC running, and use delayed action on equipment doors so technicians can move carts and racks without the door closing on them. Note that aisle containment doors inside the hall are usually sliding or specialty doors supplied by the containment manufacturer.

Tip: Coordinate the closer, electric strike and door position switch during hardware design. A closer that leaves the door a few millimeters off the strike will generate nuisance "door forced" or "held open" alarms.

Under the 2010 ADA Standards for Accessible Design (section 404), interior hinged doors must open with no more than 5 lbf, and a closer must be adjusted so the door takes at least 5 seconds to swing from 90Β° to 12Β° from the latch. Fire doors are the exception on opening force: the authority having jurisdiction sets the minimum. Always check local code and your AHJ.

Related pages: office building door closers, door closers for heavy doors and fire-rated door closers.

DRIWON DN-9500 Specifications

ModelDRIWON DN-9500 extra heavy duty commercial door closer
CertificationANSI/BHMA A156.4 Grade 1; UL listed
Fire rating3-hour fire rated when installed on a rated door assembly
Power sizeAdjustable 1–6
Door weight44–440 lbs (20–200 kg)
Door width23"–59" (58–150 cm)
Body / armExtra heavy duty cast iron body, wrought steel arm, heat-treated piston
ControlHydraulic, with delayed action and secure positive latch
FinishCorrosion-resistant powder coat, silver or black

Need the lighter-duty option for interior doors? See the DRIWON DN-8220 Grade 1 door closer. Full details on the DN-9500 product page.

Data Center Door Closer FAQ

Do server room doors need door closers?

Usually yes: server rooms are often fire rated and access controlled, and many are protected by clean agent systems that require doors to be closed.

Why are door closers important for clean agent fire suppression?

Clean agent systems need the room to hold the agent for a set time. Self-closing, latching doors are part of room integrity.

How do I stop "door held open" alarms?

Make sure the closer brings the door fully into the latch: adjust latch speed, check alignment with the strike and door position switch, and set the closer with HVAC running.

What closer works for mantrap doors?

A Grade 1 closer with consistent closing speed and a positive latch, so interlocked doors release quickly and reliably.

Can the DN-9500 handle wide equipment doors?

Yes, doors up to 59" wide and 440 lbs. Add delayed action so carts and racks can pass.

Bulk Orders & Professional Inquiries

Building or upgrading a data center or IT rooms? Contact our team for volume pricing and specifications.