Door Closers for Medical Office
Buildings & Clinics

DRIWON DN-9500 Grade 1 – a heavy duty door closer for medical office buildings, outpatient clinics, imaging centers and urgent care: suite entries, exam rooms, imaging rooms and stairs, with ADA-adjustable closing and UL fire-rated performance on rated assemblies.

For medical office buildings (MOBs), physician practices, outpatient and specialty clinics, imaging centers, dental offices and urgent care centers.

πŸ›‘οΈ ANSI / BHMA Grade 1
πŸ”₯ 3-Hour Fire Rated
πŸ› οΈ Extra Heavy Duty Cast Iron

🩺 Built for Clinics & MOBs

Suites, exam & imaging rooms

πŸ† Grade 1 Extra Heavy Duty

Tested beyond 2 million cycles

βš™οΈ Fully Adjustable 1-6

With delayed action & positive latch

πŸ”₯ UL 3-Hour Fire Rated

On rated door assemblies

DRIWON DN-9500 – Door Closer for Medical Office Buildings (Grade 1)

  • βœ… MEDICAL BUILDING DOOR HARDWARE
    Built for suite entries, corridors, exam rooms, imaging rooms and stairs.
  • βœ… ADA-ADJUSTABLE & DELAYED ACTION
    Low opening force and extra passage time for patients with mobility aids.
  • βœ… QUIET CLOSING FOR EXAM ROOMS
    Separate closing and latch speed valves keep doors from slamming.
  • βœ… GRADE 1 & UL 3-HOUR
    For rated suite entries, corridors and stair doors.
  • βœ… HEAVY DOOR CAPACITY
    Up to 440 lbs, including lead-lined imaging doors with suitable hinges.
Buy DN-9500 on Amazon

Door Hardware for Medical Office Buildings

Medical office buildings sit between offices and hospitals. Many are business occupancies, but they serve patients with walkers, wheelchairs and limited strength every day, and they often house imaging, procedure and lab spaces with special doors. Clinics where patients may be unable to evacuate on their own, such as some surgery or dialysis centers, can fall under stricter ambulatory health care requirements in NFPA 101. Confirm the occupancy for each tenant space with your AHJ.

Accessibility Is the Top Priority

Patients arrive with crutches, walkers and wheelchairs. Set opening force as low as the door allows and use delayed action on suite entries so the door does not start closing while a patient is still in the opening.

Under the 2010 ADA Standards for Accessible Design (section 404), interior hinged doors must open with no more than 5 lbf, and a closer must be adjusted so the door takes at least 5 seconds to swing from 90Β° to 12Β° from the latch. Fire doors are the exception on opening force: the authority having jurisdiction sets the minimum. Always check local code and your AHJ.

Multi-tenant buildings: landlords can simplify maintenance by setting one closer standard for all suites in the tenant design criteria, while each tenant adjusts power and speed for its own doors.

Infection Control and Cleanability

Clinic doors are touched and cleaned constantly. The DN-9500's non-porous powder-coated finish can be wiped down; verify compatibility with your disinfectants. Doors to procedure and clean rooms should close and latch reliably to support the air pressure relationships designed for them.

Specifying Closers for a Medical Office Project

  1. Confirm the occupancy of each tenant space (business or ambulatory health care).
  2. Identify rated corridors, suite entries and stairs.
  3. Record door weights, especially lead-lined and acoustic doors.
  4. Set ADA opening force and closing time after installation.
  5. Standardize on one Grade 1 model across tenants.

For full hospital guidance see our hospital door closer page and the healthcare door hardware guide.

DRIWON DN-9500 Specifications

ModelDRIWON DN-9500 extra heavy duty commercial door closer
CertificationANSI/BHMA A156.4 Grade 1; UL listed
Fire rating3-hour fire rated when installed on a rated door assembly
Power sizeAdjustable 1–6
Door weight44–440 lbs (20–200 kg)
Door width23"–59" (58–150 cm)
Body / armExtra heavy duty cast iron body, wrought steel arm, heat-treated piston
ControlHydraulic, with delayed action and secure positive latch
FinishCorrosion-resistant powder coat, silver or black

Need the lighter-duty option for interior doors? See the DRIWON DN-8220 Grade 1 door closer. Full details on the DN-9500 product page.

Medical Office Building Door Closer FAQ

What door hardware is needed in a medical office building?

Grade 1 closers on entrances, suite entries and corridors; UL listed closers on rated doors and stairs; ADA-compliant adjustment everywhere patients go; and quiet closing on exam rooms.

Do exam room doors need door closers?

Not always by code, unless the door is in a rated wall. Many clinics add closers for privacy and noise control; set them for quiet, light closing.

What closer works on lead-lined imaging room doors?

An extra heavy duty closer rated for the door weight, such as the DN-9500 (up to 440 lbs), with hinges or pivots rated for the load.

Are clinics held to hospital codes?

Most medical offices are business occupancies, but clinics treating patients who cannot evacuate on their own may be ambulatory health care occupancies under NFPA 101. Check with your AHJ.

How do I make clinic doors easier for patients?

Reduce opening force as far as the door allows, add delayed action and consider a low-energy operator at the main accessible entrance.

Bulk Orders & Professional Inquiries

Fitting out a medical office building or a group of clinics? Contact our team for volume pricing and specifications.